Sileaf-Emerge Inverter

Emerge Inverter

OFF - GRID
KEY ADVANTAGES
  • Efficiency 91%
  • Robust Design
  • Up and running even at remote locations
    across India
  • Proven track record of least maintenance
  • Seven service centers across India
MODEL NAMES:
  • EMERGE1PH
  • EMERGE3PH
Product ID: 750

Product Description

FEATURES
  • 1 to 10 KW Off-Grid
  • Superior MPPT algorithm harvesting more energy
  • Multi-level Inbuilt protections to handle the surge currents, short circuit, overloads etc.
  • Hybrid Design (Grid & Solar charging)
  • Graphical LCD display with user level settings
  • Configurable Energy management and power priorities system
VARIANTS
Single Phase PCU
MODEL NAMES RATING
EMERGE1PH5000 5 KW(96 V)
EMERGE1PH6000 6 KW (96 V)
EMERGE1PH7500 7.5 KW(96 V and 120 V)
EMERGE1PH8000 8 KW(96 V and 120 V)
EMERGE1PH10000 10 KW(120 V)
Three Phase PCU
MODEL NAMES RATING
EMERGE1PH5000 5 KW
EMERGE3PH10000 10 KW
EMERGE1PH15000 15 KW
EMERGE1PH20000 20 KW
EMERGE1PH30000 30 KW

 

1

RATING CHASIS DIMENSIONS (W x D x H)
5 to 6 KW 300 x 650 x 720

2

RATING CHASIS DIMENSIONS (W x Dx H)
7.5 to 6 KW 300 x 650 x 815

 

 

TECHNICAL SPECIFICATIONS FOR SINGLE PHASE PCU
EMERGE1PH5000 EMERGE1PH6000 EMERGE1PH7500 EMERGE1PH8000 EMERGE1PH10000
Inverter Capacity 5 KW 6 KW 7.5 KW 8 KW 10 KW

MPPT CONTROLLER

Controlling Element IGBT IGBT IGBT IGBT IGBT
MPPT Voltage Range 110-250 110-250 110-320 110-320 110-320
No. of MPPT Channels  1  1 1 1 1
MPPT Efficiency >98% >98% >98% >98% >98%

INVERTER OUTPUT

Controlling Element IGBT & ARM IGBT & ARM IGBT & ARM IGBT & ARM IGBT & ARM
Output Voltage 220-240 V 220-240 V 220-240 V 220-240 V 220-240 V
Output Frequency 47-53 Hz 47-53 Hz 47-53 Hz 47-53 Hz 47-53 Hz
Operating Temperature 0-55º 0-55º 0-55º 0-55º 0-55º
Peak Efficiency Upto 91% Upto 91% Upto 91% Upto 91% Upto 91%
Humidity 5-95%
Non-condensing
5-95%
Non-condensing
5-95%
Non-condensing
5-95%
Non-condensing
5-95%
Non-condensing
THD <3% <3% <3% <3% <3%
Cooling System Forced Cooling Forced Cooling Forced Cooling Forced Cooling Forced Cooling
Communication RS-232, RS-485
by default, CAN bus on demand
RS-232, RS-485
by default, CAN bus on demand
RS-232, RS-485
by default, CAN bus on demand
RS-232, RS-485
by default, CAN bus on demand
RS-232, RS-485
by default, CAN bus on demand

GRID CHARGING

AC Input 200-240 VAC 200-240 VAC 200-240 VAC 200-240 VAC 200-240 VAC
Frequency 47-53 Hz 47-53 Hz 47-53 Hz 47-53 Hz 47-53 Hz
Charging Current 6 A (settable) 6 A (settable) 6 A (settable) 6 A (settable) 6 A (settable)
GRID Charger Start
Voltage (Settable)
1.8-2.3 V (settable) 1.8-2.3 V (settable) 1.8-2.3 V (settable) 1.8-2.3 V (settable) 1.8-2.3 V (settable)
Grid Charger Current
(Settable)
As per battery AH As per battery AH As per battery AH As per battery AH As per battery AH

 

 

TECHNICAL SPECIFICATIONS FOR 3 PHASE PCU
EMERGE3PH5000 EMERGE3PH10000 EMERGE3PH15000 EMERGE3PH20000 EMERGE3PH30000
Inverter Capacity 5 KW 10 KW 15 KW 20 KW 30 KW

MPPT CONTROLLER

Controlling Element IGBT IGBT IGBT IGBT IGBT
MPPT Voltage Range
No. of MPPT pannels  1  1 1 1 1
MPPT Efficiency >98% >98% >98% >98% >98%

INVERTER OUTPUT

Controlling Element IGBT IGBT IGBT IGBT IGBT
Output Voltage 380-450 V 380-450 V 380-450 V 380-450 V 380-450 V
Output Frequency 47-53 Hz 47-53 Hz 47-53 Hz 47-53 Hz 47-53 Hz
Operating Temperature 0-50º 0-50º 0-50º 0-50º 0-50º
Peak Efficiency Upto 91% Upto 91% Upto 91% Upto 91% Upto 91%
Humidity 5-95%
Non-condensing
5-95%
Non-condensing
5-95%
Non-condensing
5-95%
Non-condensing
5-95%
Non-condensing
THD <3% <3% <3% <3% <3%
Cooling System Forced Cooling Forced Cooling Forced Cooling Forced Cooling Forced Cooling
Communication CAN BUS, RS-232,
RS-485 by default,
ETHERNET on demand.
CAN BUS, RS-232,
RS-485 by default,
ETHERNET on demand.
CAN BUS, RS-232,
RS-485 by default,
ETHERNET on demand.
CAN BUS, RS-232,
RS-485 by default,
ETHERNET on demand.
CAN BUS, RS-232,
RS-485 by default,
ETHERNET on demand.

GRID CHARGING

AC Input 385-460 VAC 385-460 VAC 385-460 VAC 385-460 VAC 385-460 VAC
Frequency 47-53 Hz 47-53 Hz 47-53 Hz 47-53 Hz 47-53 Hz
Charging Current 6 A (settable) 6 A (settable) 6 A (settable) 6 A (settable) 6 A (settable)
GRID Charger Start
Voltage (Settable)
1.8-2.3 VPC (settable) 1.8-2.3 VPC (settable) 1.8-2.3 VPC (settable) 1.8-2.3 VPC (settable) 1.8-2.3 VPC (settable)
Grid Charger Current
(Settable)
As per battery AH As per battery AH As per battery AH As per battery AH As per battery AH

Featured Products